- Products Description
- Main Function
- Parameters
Parameters
Function Introduction


Basic Circuit and Metering Characteristic

Saturated Condition

Under-Saturated Condition

Consumer Flows with Reduced Pump Flow

Characteristic Curve

Applications


· Proportional direct acting spool
· For fix and variable displacement pump
· Aluminum manifold
· Customized solution
· Nominal flow rating Inlet port P 80l/min Working ports 60l/min
· Maximum pressure Inlet port P 280bar Working ports 280bar Outlet port 50bar Drain port 5bar
· Ports threading P-T G1/2 G3/4 A-B G3/8 G1/2 L-M G1/4
· Compensator Inlet compensator 16bar Local compensator 5bar 8.5bar
· Notches dimension and flow rate 3 8 16 24 35 40 l/min 4 10 20 30 45 55 l/min
· On / off dump valve Power 20.5W Voltage and maximum current 12VDC @1200mA 24VDC@600mA
· Proportional valve Power 36W Voltage and maximum current 12VDC @1800mA 24VDC@900mA PWM PWM100Hz